Conventional Jacketed Vessel

A conventional jacketed vessel is a cylindrical process tank surrounded by a full-annular outer jacket circulating heating or cooling media to control batch temperature. Operating across a wide temperature range with steam, hot water, chilled water, or thermal oil as the heat transfer medium, it is the standard configuration for temperature-controlled batch processing in pharmaceutical, food, cosmetic, and chemical manufacturing.

Challenges

Uneven Temperature Distribution Across the Batch

Poor agitation or inadequate agitator selection allows thermal gradients to develop between the heated wall region and the batch centre, causing inconsistent processing particularly in viscous or poorly circulating systems.

Reduced Heat Transfer at High Viscosity

In viscous products, a stagnant fluid layer forms at the vessel wall between agitator passes, acting as an insulating film that significantly reduces the effective heat transfer rate between jacket and batch.

Jacket Pressure Rating Limiting Maximum Steam Temperature

Standard annular jackets are rated for moderate pressures, which limits the maximum steam temperature available and therefore the maximum achievable heating rate for high-temperature processes.

Scale-Up Uncertainty

Mixing behaviour observed at laboratory scale in multi-impeller configurations does not always translate directly to larger vessels due to changes in fluid dynamics with vessel geometry.

Thermal Lag in Batch Temperature Response

The mass of the vessel wall and jacket fluid introduces a delay between a change in jacket media temperature and the corresponding change in batch temperature, complicating precise temperature control during reactive or temperature-sensitive processes.

Solutions

Applications

Models & Capacities

2A  —  Conventional Jacketed Vessel (JV-C)  —  50 L to 50,000 L  —  −20 to 200°C  —  Up to 6 bar  —  U 200–1,200 W/m²·K  —  Steam / HW / CW / Oil

Model

Capacity [L]

Jacket Vol [L]

Motor [kW]

Agitator Speed [RPM]

Op. Temp [°C]

Jacket Pressure [bar]

U [W/m²·K]

Vessel H × Ø [mm]

Overall H [mm]

Weight [kg]

JV-C-050

50

8

0.37 – 0.75

20–80 VFD

−20 to 200

1 – 6

200 – 900

Ø400 × 500

1,500

80

JV-C-100

100

15

0.55 – 1.1

20–80 VFD

−20 to 200

1 – 6

250 – 1,000

Ø500 × 600

1,800

130

JV-C-300

300

35

1.1 – 2.2

15–60 VFD

−20 to 200

1 – 6

250 – 1,100

Ø700 × 900

2,400

280

JV-C-500

500

55

2.2 – 4.0

15–60 VFD

−20 to 200

1 – 6

300 – 1,100

Ø850 × 1,050

2,900

420

JV-C-1000

1,000

100

4.0 – 7.5

15–60 VFD

−20 to 200

1 – 6

300 – 1,200

Ø1,100 × 1,200

3,500

720

JV-C-3000

3,000

250

7.5 – 15

10–50 VFD

−20 to 200

1 – 6

300 – 1,200

Ø1,500 × 1,700

4,500

1,800

JV-C-10000

10,000

700

15 – 37

10–40 VFD

−20 to 200

1 – 6

250 – 1,100

Ø2,400 × 2,500

6,500

5,200

JV-C-50000

50,000

3,000

37 – 90

5–30 VFD

−20 to 200

1 – 6

200 – 1,000

Ø4,500 × 4,800

10,000

18,000

 

×