Loss-in-Weight Gravimetric Micro Feeder

A loss-in-weight feeder mounts a screw or twin screw metering unit and its hopper on precision load cells and controls screw speed to hold the measured rate of weight loss exactly at setpoint. It converts volumetric metering into true mass flow control with 0.25 to 0.5 percent accuracy, the standard for recipe-critical continuous dosing from 0.1 to 300 kg/h.

Challenges

Weight Signal Corruption by Plant Vibration

Floor and machine vibration superimposes noise on the load cell signal, degrading rate resolution at micro feed rates.

Accuracy Loss During Refill

During hopper refill the weight signal rises, blinding the gravimetric loop exactly when feed must continue.

Pipe and Sleeve Forces on the Weighed Mass

Rigid connections to refill and discharge lines shunt force around the load cells, biasing the measurement.

Pressure Transients from Downstream Equipment

Suction or pressure pulses from receiving mixers and conveyors act on the weighed hopper as false weight changes.

Calibration and Verification Burden

Regulated processes demand documented proof that the indicated rate equals true mass flow over time.

Solutions

Applications

Model Range and Capacity: JBM-MF-W Series

Basis: Accuracy as 2-sigma deviation over 1-minute samples at mid-range, SS 316L contact parts.

ModelMetering ScrewFeed Rate (kg/h)Accuracy (2-sigma)Hopper (L)RefillContact Material
JBM-MF-W05Single 12 mm0.1 – 2.40.5 %5Pneumatic valveSS 316L
JBM-MF-W15Single 20 mm0.3 – 150.5 %10Pneumatic valveSS 316L
JBM-MF-W50Twin 30 mm1 – 360.25 %25Vacuum refillSS 316L
JBM-MF-W150Twin 40 mm2.5 – 900.25 %50Vacuum refillSS 316L
JBM-MF-W300Twin 50 mm5 – 1800.25 %75Vacuum refillSS 316L
×